Project: Guard filter

Project

Guard filter

An industrial-sized guard filter was installed after a hot gas cooler, which uses hourly 170.000 m³ of air.

The guard filter was installed to minimize diffuse dust emissions into the environment. Since commissioning in 2023, the filter plant comfortably meets the guaranteed emission level of less than 0.2 mg/Nm³.

Category

Specifications

Application Police filter after hot gas cooler
Start-up date 2023
Type of Filter MPF 4-6-11/2-2x
Filter surface 3.700 m²
Gas flow 170.000 Nm³/hr
Design Temperature 100°C
Design Pressure -650 daPa

Impressions

Other projects in the same industry

175.000 m³/hr

During the shutdown of only 20 days, the existing filter was dismantled and the new stainless steel filter was fully constructed & successfully commissioned. It […]

550.000 m³/hr

A high-capacity tertiary filter plant to prevent diffuse emissions of lead particles. The filter plant has a modular design, making it suitable for very high […]

35.000 m³/hr

An ATEX filter has been installed in an explosive environment. The filter installation is engineered for a maximum overpressure of 400 mbar and is equipped […]

Ready to elevate your project? Let's discuss your goals and create a custom solution

Our expertise isn’t just in filters, it’s in foresight. We understand what downtime means for your business. We move with purpose to restore flow.