Project: Bag house revamp
Project
Bag house revamp
Due to extreme wear of the filter base plates and cleaning system, despite the applied glass flake coating, there were continuous dust emissions and the installation could no longer be operated reliably. In the shutdown all carbon steel filter base plates and cleaning system were fully replaced with Duplex plates and 1.4462 cleaning system and fully welded, after which the coating was reapplied to all transitions between steel and duplex.
Specifications
Impressions
Other projects in the same industry
An electrostatic precipitator was upgraded to increase electrode spacing combined with installing 3-phase transformers and raise internal design temperatures to 450°C, by altering the material […]
Seven stainless steel chimneys including horizontal flue gas exhaust ducts in material grade 1.4571 were engineered for corrosion-resistant exhaust discharge. The design and choice of […]
For a client in the WTE sector with 7 incineration lines, each equipped with 2 ESP’s, we provide scheduled and ad-hoc maintenance on the ESP’s […]
Ready to elevate your project? Let's discuss your goals and create a custom solution
Our expertise isn’t just in filters, it’s in foresight. We understand what downtime means for your business. We move with purpose to restore flow.